描述
Product name | Specifications | Format | |||
---|---|---|---|---|---|
Screen size |
Number Of Dots | Ethernet | Frame Color | ||
NS5-V2 Main Unit*1 |
5.7-inch TFT*2 (color) LED backlight |
320 × 240 dots |
No | Ivory | NS5-SQ10-V2 |
Black | NS5-SQ10B-V2 | ||||
Yes | Ivory | NS5-SQ11-V2 | |||
Black | NS5-SQ11B-V2 | ||||
5.7-inch high-luminance TFT *2 (Color) LED backlight |
No | Ivory | NS5-TQ10-V2 | ||
Black | NS5-TQ10B-V2 | ||||
Yes | Ivory | NS5-TQ11-V2 | |||
Black | NS5-TQ11B-V2 | ||||
NS8-V2 main unit |
8.4-inch TFT*2 LED backlight |
640 × 480 dots |
Yes | Black | NS8-TV01B-V2 |
NS10-V2 Main Unit |
10.4-inch TFT*2 LED backlight |
640 × 480 dots |
No | Ivory | NS10-TV00-V2 |
Black | NS10-TV00B-V2 | ||||
Yes | Ivory | NS10-TV01-V2 | |||
Black | NS10-TV01B-V2 | ||||
NS12-V2 Main Unit |
12.1-inch TFT*2 LED backlight |
800 × 600 dots |
No | Ivory | NS12-TS00-V2 |
Black | NS12-TS00B-V2 | ||||
Yes | Ivory | NS12-TS01-V2 | |||
Black | NS12-TS01B-V2 | ||||
NSH5-V2 Main Unit *1 (Hand-Held Type) |
5.7 inch TFT |
320 × 240 dots |
No | Black (Emergency stop switch: red) |
NSH5-SQG10B-V2 |
Series | NS5-V2 | NS8-V2 | NS10-V2 | NS12-V2 |
---|---|---|---|---|
Rated power supply voltage | 24 V DC | |||
Allowable power supply voltage range | 20.4 to 27.6 V DC (24 V DC ±15%) | |||
Power consumption | 15 W or less | 25 W or less | ||
Ambient operating temperature | 0 to 50°C Note: The ambient operating temperature is subject to the following restrictions according to the mounting angle. Mounting angle of 0 to 30° to the horizontal: · When no expansion units are mounted, the operating temperature range is 0 to 45°C · When a video input unit or a controller link interface unit is mounted, the ambient operating temperature is 0 to 35°C. Mounting angle of 30 to 90° to the horizontal: ambient operating temperature range of 0 to 50°C (0 to 45°C for NS8) |
|||
Ambient storage temperature | -20 to +60°C | |||
Ambient operating humidity | 35 to 85% RH (0 to 40°C), 35 to 60% RH (40 to 50°C) No condensation | |||
Operating ambient atmosphere | No corrosive gas | |||
Noise resistance | IEC61000-4-4 compliant 2 kV (power supply line) | |||
Vibration resistance (during operation) | 10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, 9.8 m/s2 each in X, Y, and Z directions | |||
Shock resistance (during operation) | 147 m/s2 3 times each in direction of X, Y, and Z | |||
Mass | 1.0 kg or less | 2.0 kg or less | 2.3 kg or less | 2.5 kg or less |
Protective structure | Front operating panel: IP65 oil-proof type and NEMA4-equivalent UL type 4. *1 Note: May not be applicable in locations with long-term exposure to oil. |
|||
Grounding | D type grounding (No. 3 type grounding) | |||
Battery life | Battery life: 5 years (at 25°C): Replace battery within 5 days after the battery runs low (indicator lights orange) | |||
Applicable standards | Certified for conformance to UL 508, UL 1604, EMC directives, NK, and LR standards |
Series | NSH5-V2 | |
---|---|---|
Type | Type Color TFT 5.7 Inch (Hand-Held Type) | |
Frame color | Black | |
Built-in Ethernet port | No | |
Format | Model NSH5-SQR10B-V2 (emergency stop switch: red) | |
Rated power supply voltage | 24 V DC | |
Allowable power supply voltage range | 20.4 to 27.6 V DC (24 V DC ±15%) | |
Power consumption | 10 W or less | |
Ambient operating temperature | 0 to 40°C | |
Ambient storage temperature | −20 to +60°C | |
Ambient operating humidity | 35 to 85% RH (0 to 40°C) No condensation | |
Operating ambient atmosphere | No corrosive gas | |
Noise resistance | Common mode: 1,000 Vp-p (between power supply terminals and panel) Normal mode: 300 Vp-p Pulse width: 100 ns to 1 ms, Rise time: 1-ns pulse |
|
Vibration resistance (during operation) | 10 to 57 Hz, 0.075 mm amplitude, 57 to 150 Hz, 9.8 m/s2 each in X, Y, and Z directions | |
Shock resistance (during operation) | 147 m/s2 3 times each in direction of X, Y, and Z | |
Mass | 1 kg or less | |
Protective structure | IP65 equivalent | |
Grounding | D type grounding (No. 3 type grounding) | |
Battery life | Battery life: 5 years (at 25°C) Replace battery within 5 days after the battery runs low (indicator lights orange) |
|
Applicable standards | Certified for conformance to UL 508, EMC directives, and EN 60204-1 |